  • What should I do if boiler water is insufficient?Open or Close

    Check the following:
    Is there water in the soft water tank?
    Is there a false water level in the water level gauge?

    If the problem still exists, please contact Zu How Service Center for further assistance.

  • Brief Codes for LPG Safety in TaiwanOpen or Close

    Brief Codes for LPG Safety in Taiwan

    1. Storing LPG storage containers in a basement
    2. Without safety signs of No Open Flames or without fire extinguishers
    3. Without placing gas leakage alarm devices
    4. All compressed gas cylinders (including empty ones) without being secured in an upright position at all times, or not being secured to prevent accidental falling

    2. In principle, gas cylinders shall be stored outside. Storing inside of buildings shall be in well-ventilated areas, and avoid low-lying areas, staircases, or areas that allow the contents to settle.

    3. The location of using LPG cylinders in parallel shall be inspected monthly, including the following items:

    1. Safety signs of No Open Flames
    2. Fire extinguishers
    3. The location of LPG cylinders
    4. Measures to avoid falling
    5. Measures to avoid direct sunlight
    6. Gas pipes
    7. Rubber hoses
    8. Gas leakage alarm devices

    4. The quantity of LPG stored in special buildings or rooms must not exceed 1000kg.

    5. Location of gas leakage alarm devices: For LNG storage, the gas detector placement shall have a distance up to 30cm from the ceiling, and have a minimum distance of 3m away from a gas-fire appliance. For LPG storage, the gas detector placement shall have a distance up to 30cm from the floor, and have a minimum distance of 3m away from a gas-fire appliance.

  • Brief Codes for Boiler Room Safety in TaiwanOpen or Close

    1. At least two separate exits shall be provided from each boiler room, except that there's no interference from boiler operators having quick retreat.

    2. A minimum unobstructed clearance from the top of the boiler to the ceiling, beam, piping, or other objects shall be 1.2 meters, except that there's no interference from the inspection, adjustment, and operation of the valves and other equipment.

    3. The vertical boiler or the exterior boiler without any coverings shall have a minimum unobstructed clearance of 45cm from all service sides of the boiler to the wall, piping, or another boiler; moreover, the boiler's combustion chamber with an internal diameter of 500mm maximum, and with 1000mm maximum in length, shall have a minimum unobstructed clearance of 30cm.

    4. If the boiler and its metal chimneys or flue pipes are not covered with non-metallic and non-combustible materials with a minimum thickness of 10cm, none of any combustible materials shall be placed within 15cm of the exterior boiler, except for the case that the combustible materials are covered with non-metallic and non-combustible materials.

    5. Fuel storage in boiler rooms or boiler installation site, the solid fuels shall be at least 1.2m away from the exterior boiler, and the liquid fuels or fuel gases must be at least 2m away from the exterior boiler. However, by the installation of proper fire barriers or other fire-resistive barriers, the range of clearance between the boiler and the fuels or fuel containers are able to be lower.

  • What should I do if the capability of feed water pump is insufficient?Open or Close

    Check the following:
    Is the valve fully open?
    Is there any blockage at the strainer?
    Is the feed water check valve functioning?

    If the problem still exists, please contact Zu How Service Center immediately, our technicians will be at your service.

  • Prevention of Gas Boiler ExplosionOpen or Close

    1. Develop a periodic maintenance schedule.

    2. Rate all piping and components for safety design.

    3. Design boiler installation room with good ventilation.

    4. Install gas leakage protection & shutdown System

    5. Provide boiler operators professional on-the-job training.

    6. Establish a safety testing program to reduce the risk of machine failures.

    7. Conduct air-fuel ratio inspection.

    8. Carry out boiler water quality monitoring.

  • What should I do if the boiler water level is low?Open or Close

    Check the following:
    Is there water in the soft water tank?
    Is the water pump vented?

    If the problem still exists, please contact Zu How Service Center immediately, our technicians will be at your service.

  • What should I do if the boiler water level is high?Open or Close

    Open the boiler blow down valve and relief valve to drain the boiler water.

    If the problem still exists, please contact Zu How Service Center immediately, our technicians will be at your service.

  • What should I do if the water level gauge is not working?Open or Close

    Check if the wire of the water level electrode is connected properly.

    If the problem still exists, please contact Zu How Service Center immediately, our technicians will be at your service.